Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mikrochim Acta ; 191(3): 134, 2024 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353778

RESUMO

Salivary pH serves as a valuable and useful diagnostic marker for periodontal disease, as it not only plays a critical role in disease prevention but also in its development. Typically, saliva sampling is collected by draining and spitting it into collection tubes or using swabs. In this study, we have developed a Point-of-Care (POC) device for in situ determination of oral pH without the need for complex instruments, relying solely on a smartphone as the detection device. Our system utilizes a non-toxic vegetable colourimetric indicator, immobilized on a chitosan membrane located on a disposable stick, enabling direct sampling within the buccal cavity. An ad hoc designed 3D-printed attachment is used to ensure accurate positioning and alignment of the stick, as well as isolation from external lighting conditions. A custom-developed smartphone application captures and automatically processes the image of the sensing membrane, providing the salivary pH results. After optimizing the cocktail composition, the developed sensors demonstrated the capacity to determine pH within a range of 5.4 to 8.1 with a remarkable precision of 0.6%, achieving a very short analysis time of just 1 min. A stability study conducted on the sensing membranes revealed a lifetime of 50 days. To validate the performance of our analytical device, we compared its results against those obtained from a calibrated pH-meter, using a group of individuals. The device exhibited an average error of 2.4% when compared with the pH-meter results, confirming its reliability and accuracy.


Assuntos
Quitosana , Smartphone , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes , Concentração de Íons de Hidrogênio
2.
Lab Chip ; 23(18): 4092-4103, 2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37615614

RESUMO

Understanding the phenomenon of liquid wicking in porous media is crucial for various applications, including the transportation of fluids in soils, the absorption of liquids in textiles and paper, and the development of new and efficient microfluidic paper-based analytical devices (µPADs). Hence, accurate and real-time monitoring of the liquid wicking process is essential to enable precise flow transport and control in microfluidic devices, thus enhancing their performance and usefulness. However, most existing flow monitoring strategies require external instrumentation, are generally bulky and unsuitable for portable systems. In this work, we present a portable, compact, and cost-effective electronic platform for real-time and wireless flow monitoring of liquid wicking in paper strips. The developed microcontroller-based system enables flow and flow rate monitoring based on the capacitance measurement of a pair of electrodes patterned beneath the paper strip along the liquid path, with an accuracy of 4 fF and a full-scale range of 8 pF. Additionally to the wired transmission of the monitored data to a computer via USB, the liquid wicking process can be followed in real-time via Bluetooth using a custom-developed smartphone application. The performance of the capacitive monitoring platform was evaluated for different aqueous solutions (purified water and 1 M NaCl solution), various paper strip geometries, and several custom-made chemical valves for flow retention (chitosan-, wax-, and sucrose-based barriers). The experimental validation delivered a full-scale relative error of 0.25%, resulting in an absolute capacitance error of ±10 fF. In terms of reproducibility, the maximum uncertainty was below 10 nl s-1 for flow rate determination in this study. Furthermore, the experimental data was compared and validated with numerical analysis through electrical and flow dynamics simulations in porous media, providing crucial information on the wicking process, its physical parameters, and liquid flow dynamics.

3.
Biosens Bioelectron ; 230: 115268, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37030262

RESUMO

The COVID-19 pandemic has highlighted the need for innovative approaches to its diagnosis. Here we present CoVradar, a novel and simple colorimetric method that combines nucleic acid analysis with dynamic chemical labeling (DCL) technology and the Spin-Tube device to detect SARS-CoV-2 RNA in saliva samples. The assay includes a fragmentation step to increase the number of RNA templates for analysis, using abasic peptide nucleic acid probes (DGL probes) immobilized to nylon membranes in a specific dot pattern to capture RNA fragments. Duplexes are formed by labeling complementary RNA fragments with biotinylated SMART bases, which act as templates for DCL. Signals are generated by recognizing biotin with streptavidin alkaline phosphatase and incubating with a chromogenic substrate to produce a blue precipitate. CoVradar results are analysed by CoVreader, a smartphone-based image processing system that can display and interpret the blotch pattern. CoVradar and CoVreader provide a unique molecular assay capable of detecting SARS-CoV-2 viral RNA without the need for extraction, preamplification, or pre-labeling steps, offering advantages in terms of time (∼3 h/test), cost (∼€1/test manufacturing cost) and simplicity (does not require large equipment). This solution is also promising for developing assays for other infectious diseases.


Assuntos
Técnicas Biossensoriais , COVID-19 , Aplicativos Móveis , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , RNA Viral/genética , RNA Viral/análise , Pandemias , Técnicas Biossensoriais/métodos , Smartphone , Técnicas de Amplificação de Ácido Nucleico/métodos
4.
Sensors (Basel) ; 22(11)2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35684732

RESUMO

In this work, we present a ballistocardiographic (BCG) system for the determination of heart and breath rates and activity of a user lying in bed. Our primary goal was to simplify the analog and digital processing usually required in these kinds of systems while retaining high performance. A novel sensing approach is proposed consisting of a white LED facing a digital light detector. This detector provides precise measurements of the variations of the light intensity of the incident light due to the vibrations of the bed produced by the subject's breathing, heartbeat, or activity. Four small springs, acting as a bandpass filter, connect the boards where the LED and the detector are mounted. Owing to the mechanical bandpass filtering caused by the compressed springs, the proposed system generates a BCG signal that reflects the main frequencies of the heartbeat, breathing, and movement of the lying subject. Without requiring any analog signal processing, this device continuously transmits the measurements to a microcontroller through a two-wire communication protocol, where they are processed to provide an estimation of the parameters of interest in configurable time intervals. The final information of interest is wirelessly sent to the user's smartphone by means of a Bluetooth connection. For evaluation purposes, the proposed system has been compared with typical BCG systems showing excellent performance for different subject positions. Moreover, applied postprocessing methods have shown good behavior for information separation from a single-channel signal. Therefore, the determination of the heart rate, breathing rate, and activity of the patient is achieved through a highly simplified signal processing without any need for analog signal conditioning.


Assuntos
Balistocardiografia , Humanos , Balistocardiografia/métodos , Frequência Cardíaca/fisiologia , Processamento de Sinais Assistido por Computador , Sono
5.
Biosens Bioelectron ; 165: 112333, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32729478

RESUMO

Concentration of α-amylase in human serum is a key indicator of various pancreatic ailments and an affordable point-of-care detection of this biomarker can benefit millions suffering from these diseases. In view of this situation, we report the development of a flexible patch-sensor, which simply requires a microdroplet of aqueous starch-FeSO4 solution to detect α-amylase in serum. The detection is achieved through the generation of mixing vortices (~12 rpm) inside the droplet with the help of an imposed thermal gradient. Such vortices due to Marangoni and natural convections are found to be strongest at an optimal temperature difference of ~18 °C - 23 °C across the droplet which in turn facilitate mixing and promote the specific starch-amylase enzymatic reaction. Subsequently, the large (~80%) variation in the electrical resistance across the droplet is correlated to detect the level of the α-amylase in the analyte. Importantly, the sensor can detect even in the limits of 15-110 units/liter. Further, the sensitivity of flexible sensors is ~8.6% higher than the non-flexible one. Interestingly, the sensitivity of the proposed sensor has been nearly three-times than the previously reported optical ones. The results of patch-sensor match very closely with the standard path-lab tests while detecting unknown level of amylase in serum. The prototype has shown significant potential to translate into an affordable device for the real-time detection and easy prognosis of pancreatic disorders.


Assuntos
Técnicas Biossensoriais , alfa-Amilases , Amilases , Humanos , Soro , Amido
6.
Sensors (Basel) ; 20(6)2020 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-32168978

RESUMO

Safe quality control of radiotherapy treatments lies in reliable dosimetric sensors. Currently, ionization chambers and solid-state diodes along with electrometers as readout systems are accomplishing this task. In this work, we present a well-known and low-cost semiconductor sensor, the light-dependent resistor (LDR), as an alternative to the existing sensing devices for dosimetry. To demonstrate this, a complete characterization of the response to radiation of commercial LDRs has been conducted in terms of sensitivity, reproducibility and thermal correction under different bias voltages. Irradiation sessions have been applied under the common conditions in radiotherapy treatments using a hospital linear accelerator. Moreover, the same electrometer used for the ionization chamber has also been successfully used for LDRs. In comparison with the sensitivity achieved for the ionization chamber (0.2 nC/cGy at 400 V bias voltage), higher sensitivities have been measured for the proposed LDRs, ranging from 0.24 to 1.04 nC/cGy at bias voltages from 30 to 150 V, with a reproducibility uncertainty among samples of around 10%. In addition, LDR temperature dependence has been properly modeled using the simple thermistor model so that an easy thermal drift correction of dose measurements can be applied. Therefore, experimental results show that LDRs can be a reliable alternative to dosimetric sensors with the advantages of low size, affordable cost and the fact that it could be adopted with minimal changes in routine dosimetry quality control since the same readout system is fully compatible.


Assuntos
Eletrônica Médica/instrumentação , Radiometria/instrumentação , Dosagem Radioterapêutica , Equipamentos e Provisões Elétricas , Eletrônica Médica/normas , Desenho de Equipamento , Luz , Modelos Biológicos , Sensibilidade e Especificidade , Temperatura
7.
Biosens Bioelectron ; 141: 111360, 2019 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-31176114

RESUMO

A versatile, compact and low-cost analytical platform has been designed, tested and validated to be used in the point-of-care settings. This passive measurement system is powered and complemented by a standard smartphone including a programmed application for measurement configuration and data processing as well as wireless results sharing. Electrochemical and electrochemiluminescence analytical techniques can be configured and realized by this platform that employs standard screen-printed electrodes for the sample managing and off-the-shelf electronic components. The power, electrical and optical signal processing have been studied in depth. The system can harvest energy up to 22.5 mW, set up a voltage in the range of ±1.15 V, and measure potentials in a range of 600 mV with an uncertainty of 1 mV, and current from 2 µA to 0.75 mA with a resolution of 1.1 µA. Moreover, standard tests have been performed to the platform consisting of amperometric, potentiometric, cyclic voltammetry and electrochemiluminescent analytical techniques, showing excellent agreement with a reference instrument. Finally, our design has also been applied to glucose, pH and H2O2 determinations, providing the full analytical parameters which are in very good agreement with the reference instrument results. Ranges (0.065-0.75 M, 0.62-100 mM and 3-9 pH units for glucose, H2O2 and pH, respectively) and limits of detection (0.024 M and 0.03 mM for glucose and H2O2, respectively) make this low-cost platform (

Assuntos
Técnicas Biossensoriais/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Smartphone/instrumentação , Desenho de Equipamento , Glucose/análise , Humanos , Peróxido de Hidrogênio/análise , Concentração de Íons de Hidrogênio , Limite de Detecção , Tecnologia sem Fio/instrumentação
8.
Sensors (Basel) ; 16(7)2016 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-27428973

RESUMO

This work presents the design, fabrication, and characterization of a passive printed radiofrequency identification tag in the ultra-high-frequency band with multiple optical sensing capabilities. This tag includes five photodiodes to cover a wide spectral range from near-infrared to visible and ultraviolet spectral regions. The tag antenna and circuit connections have been screen-printed on a flexible polymeric substrate. An ultra-low-power microcontroller-based switch has been included to measure the five magnitudes issuing from the optical sensors, providing a spectral fingerprint of the incident electromagnetic radiation from ultraviolet to infrared, without requiring energy from a battery. The normalization procedure has been designed applying illuminants, and the entire system was tested by measuring cards from a colour chart and sensing fruit ripening.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...